One page to answer the question every pipe buyer asks twice: which SDR do I need, and what pressure does it actually hold?

SDROD ÷ wall thickness
PNbar at 20 °C
MaterialPE100, MRS 10 MPa
Design factorC = 1.25 (water)
RangeSDR41 – SDR7.4

The two numbers are the same fact, written differently

SDR is outside diameter divided by wall thickness. A lower SDR means a thicker wall. PN is the nominal pressure in bar at 20 °C and follows from the wall:

PN = 2 × σs × 10 / (SDR − 1), σs = MRS / C

For PE100 water pipe (MRS 10 MPa, C 1.25 → σs 8 MPa) this gives the familiar pairs: SDR26 = PN6, SDR17 = PN10, SDR13.6 = PN12.5, SDR11 = PN16, SDR9 = PN20, SDR7.4 = PN25.

Temperature, and what it does to the number

PN is defined at 20 °C. Above that the allowable stress drops, so the same pipe holds less pressure. Derating factors are published by the resin supplier; for water service the usual order is roughly 0.87 at 30 °C and 0.74 at 40 °C.

Two practical consequences: a PN10 line carrying warm water may need SDR13.6 or SDR11, and a line with pump surge should be specified one class up regardless of the static head.

FULL TABLE

Wall thickness and weight, OD20 to OD630

Seven SDR classes. Upper number in each cell is wall thickness e (mm), lower number is mass per metre (kg/m).

Ask for a size not listed
OD
(mm)
Wall thickness e (mm) / weight (kg/m)
SDR 41PN4SDR 26PN6SDR 17PN10SDR 13.6PN12.5SDR 11PN16SDR 9PN20SDR 7.4PN25
200.50.030.80.051.20.071.50.081.80.12.20.122.70.14
250.60.041.00.071.50.111.80.132.30.162.80.193.40.22
320.80.071.20.111.90.172.40.212.90.253.60.314.30.36
401.00.121.50.172.40.272.90.323.60.394.40.475.40.56
501.20.181.90.272.90.413.70.514.50.615.60.756.80.88
631.50.282.40.443.70.664.60.815.70.987.01.188.51.39
751.80.42.90.634.40.935.51.156.81.398.31.6610.11.97
902.20.583.50.915.31.356.61.658.22.0110.02.412.22.85
1102.70.874.21.336.52.028.12.4810.03.012.23.5814.94.25
1253.01.14.81.737.42.619.23.211.43.8913.94.6316.95.48
1403.41.395.42.188.23.2410.34.0112.74.8515.65.8218.96.87
1603.91.836.22.869.44.2511.85.2514.56.3317.87.5921.68.97
1804.42.326.93.5810.65.3913.26.6116.48.0520.09.624.311.35
2004.92.877.74.4411.86.6614.78.1718.29.9322.211.8427.014.01
2255.53.628.75.6513.28.3916.510.3220.512.5825.015.030.417.75
2506.14.469.66.9214.710.3818.412.7922.715.4827.818.5333.821.92
2806.85.5710.88.7216.513.0420.616.0325.519.4731.123.2237.827.47
3157.77.112.111.018.516.4623.220.3128.624.5735.029.442.634.82
3558.79.0413.714.0320.920.9526.125.7532.331.2739.437.3148.044.21
4009.811.4715.417.7723.526.5529.432.6936.439.7144.447.3754.156.14
45011.014.4917.322.4626.533.6733.141.440.950.250.060.060.871.0
50012.217.8519.227.729.441.5136.851.1445.562.0455.674.1367.687.7
56013.722.4521.534.7432.952.0341.264.1350.977.7562.292.975.7109.99
63015.428.424.243.9837.165.9946.381.0857.398.4570.0117.6185.1139.12

e = OD ÷ SDR, mass at 955 kg/m³ (calculated). Confirm against the ISO 4427-2 / ISO 4437 thickness table before publishing; OD above 630 mm and SDR33/41 on request.

How to read it on a drawing

  • “DN315 PE100 SDR17” fixes OD 315 and wall ≈ 18.5 mm → PN10
  • If the drawing says only “PN10”, the SDR is implied by the material
  • PE80 at the same SDR gives a lower PN — check the material, not just the SDR
  • Weight per metre is what your freight and lifting plan needs, not the OD

Where this table stops

Above OD630 the wall thickness table changes shape and SDR33/SDR41 appear for low-pressure irrigation and gravity work. Those sizes are quoted per order — send the diameter and the pressure and we return the datasheet rather than extrapolating.